Skip to main content

AgendaQuick™

View Agenda Item

5.E.
Special Magistrate Hearing
Meeting Date:
06/06/2018
Re
Case #16-1444 - 413 N 6th St.
Submitted For:
Shaun Coss

Information

SUBJECT:

16-1444
BLDG
413 N 6th St. Simone (LF EST), Michael Shaun Coss

CASE INFORMATION:

Case Initiated: June 9, 2016 Type of Presentation: Regular

OWNER:

OWNER:
Michael Simone (LF EST)
Michael Simone (TR)
424 N 7th St.
Ft Pierce, FL 34950
OCCUPIED BY:



 

VIOLATIONS:

Section(s): 5-1.101.2.1 Unsafe Building
5-1.105.1 Permit Required
IPMC 304.6 Exterior Walls
IPMC 304.13 Windows, Doors & Frames
IPMC 304.15 Exterior Doors
IPMC 305.2 Structural Members
IPMC 305.3 Interior Surfaces
IPMC 309.1 Infestation
IPMC 505.1 Water System
IPMC 506.2 Sanitary Drainage System Maintenance
IPMC 603.1 Mechanical Equipment
IPMC 605.1 Electrical Equipment
IPMC 605.2 Electrical Receptacles
IPMC 704.2 Smoke Alarms

CORRECTIVE ACTIONS:

  1. Have the property professionally treated for the termite and rodent infestation.
  2. Seal all holes in the exterior of the structure allowing entry of rodents.
  3. Repair and/or replace smoke alarms as required.
  4. The water heater was replaced without a permit.  Hire a properly licensed plumber to obtain a permit for the water heater replacement and to bring the water heater installation up to code.
  5. Hire a properly licensed plumber to obtain a permit for the piping to the washing machine, to plumb the washing machine to the sanitary drain line and to provide shelter from the weather for the washing machine; or remove the washing machine and all piping.
  6. It is prohibited for the shower/bathtub to drain on the ground.  Hire a properly licensed plumber to repair or replace the piping as needed.
  7. The walls surrounding the shower/tub need to be repaired or replaced where the wall has become damaged.
  8. Repair or replace all damaged window glazing, hardware and locks.  Windows must be weathertight and operable.
  9. Repair or replace all damaged exterior doors and/or door frames. 
  10. Hire a properly licensed electrician to repair the defective electrical outlets throughout the house. 
  11. Hire a properly licensed electrician to bring the electrical disconnect box up to code.
  12. Install faceplates where missing or damaged on electrical receptacles.
  13. Install proper covers over exposed electrical wiring in the bedroom.
  14. Repair or replace the sub-floor where it is deteriorated, or provide documentation from a design professional that the sub-floor is structurally sound.
  15. Repair, replace or remove the paneling on the ceiling in the kitchen where it is sagging and is not properly secured.
  16. Hire a properly licensed contractor to repair or replace all termite damaged wood on the interior and exterior of the structure. 

RECOMMENDATION:

The City requests that if the Special Magistrate finds the violation exists, the violator(s) be given 60 days to obtain a permit and comply with all permit conditions or a fine of $100.00 per day be assessed.
 

Form Review

Form Started By:
Shaun Coss
Started On:
01/30/2018 10:47 AM
Final Approval Date:
04/26/2018