5.J.
Special Magistrate Ross Hearing
Meeting Date:
06/21/2017
Re
Case #16-0025 - 642 S 13th St.
Submitted For:
Shaun Coss

Information

SUBJECT:

16-0025 642 S 13th St. Jewdun, Christopher Shaun Coss

CASE INFORMATION:

Case Initiated:  January 5, 2016 Type of Presentation: Regular

OWNER:

OWNER:
Christopher Jewdun
642 S 13th St.
Ft. Pierce, FL 34950
OCCUPIED BY:


 

VIOLATIONS:

Section(s): 5-1.101.2.1 Unsafe Building
Section(s): 5-1.105.1 Permit Required
IPMC 108.1.1 Unsafe Structure
IPMC 108.1.2 Unsafe Equipment
IPMC 108.1.3 Structure Unfit for Human Occupancy
IPMC 304.1 Exterior Structure
IPMC 304.7 Roofs & Drainage
IPMC 304.10 Stairways, Decks, Porches & Balconies
IPMC 304.13 Windows, Doors & Frames
IPMC 304.13.1 Glazing
IPMC 304.15 Exterior Doors
IPMC 305.2 Structural Members
IPMC 305.3 Interior Surfaces
IPMC 305.4 Walking Surfaces
IPMC 305.6 Interior Doors
IPMC 504.1 Plumbing Fixtures
IPMC 505.1 Water System
IPMC 506.2 Sanitary Drainage System Maintenance
IPMC 603.1 Mechanical Equipment
IPMC 605.1 Electrical Equipment
IPMC 605.2 Electrical Receptacles
IPMC 605.4 Wiring
IPMC 704.2.1 Smoke Alarms

CORRECTIVE ACTIONS:

1. Repair or replace all damaged floor joists.
2. Repair all cracking in exterior walls and foundation.
3. Repair or replace the roof where it is damaged.  Repair or replace all flashing.
4. Repair or replace all broken windows, doors and hardware.
5. Repair or replace all damaged interior surfaces.
6. Repair or replace the sub-floor where it is damaged.
7. Repair or replace the stairs so that they provide a level walking surface.
8. Replace missing handrails on the stairs.
9. Repair or replace all damaged interior doors.
10. Repair all damaged, leaking, and un-permitted plumbing alterations that may cause the water source to become
contaminated.
11. Connect the washing machine to the sanitary sewer system.
12. Replace sewer lines that have been repaired and do not meet code.
13. Obtain a permit and correct the installation of the water heater.
14. Remove all unsafe electrical wiring.  Remove the flexible wiring running through the walls.
15. Replace the missing breaker panel cover.
16. Replace electrical faceplates where they are missing.
17. Replace all damaged and missing smoke alarms as required.

RECOMMENDATION:

The City requests that if the Special Magistrate finds the violation exists, the violator(s) be given 90 days to obtain a permit and comply with all permit conditions or a fine of $100.00 per day be assessed.
 

Form Review

Form Started By:
Shaun Coss
Started On:
05/24/2017 04:09 PM
Final Approval Date:
06/15/2017